Continuous Emissions Monitors


California Analytical Model 300HFID
Total Hydrocarbon Analyzer



The California Analytical Model 300HFID THC analyzer incorporates a heated flame ionization detector. The instrument, unlike most other THC analyzers, uses capillary tubes and electronic pressure controllers for gas pressure regulation. That means no more manual back pressure regulator! The instrument incorporates front panel diagnostics for troubleshooting. The instrument is set up for calibrations using propane gas standards, but can be re-optimized to calibrate using methane standards. Ranging is selectable from 10 ppm to 30,000 ppm.

Manufacturer California Analytical Instruments
Analysis Method Flame Ionization Detector
Range 10 to 30,000 ppm
Response Time 90% of full scale in 1.5 seconds
Sample Flow Rate 3 liter/min. + 1.5 liter/ min.
Noise Less than 0.5% of full scale
Zero & Span Drift Less than 1% of full scale per 24 hours
Analog Output 0 -10 VDC and 4 to 20mA DC
Power 115VAC
Dimensions 5 1/4”H x 19”W x 8”D
Weight 38 lbs

MSA Model 8800 Total Hydrocarbon Analyzer

The MSA Model 8800 THC analyzer incorporates a heated flame ionization detector. The instrument is microprocessor controlled and also uses capillary tubes for gas pressure regulation. Although the instrument incorporates a manual back pressure regulator, the regulator is highly accurate and does not require constant adjustment. The instrument incorporates front panel diagnostics for troubleshooting. Calibrations using either methane or propane are accomplished with the push of a button. Ranging is user defined from 10 ppm to 100% (and linear above 30,000 ppm!).

Manufacturer Mine Safety Appliances (MSA)
Analysis Method Flame Ionization Detector
Range 10 ppm to 100%
Response Time 90% of full scale in <10 seconds
Sample Flow Rate 1 to 3 liter/ min.
Zero & Span Drift + 1% per 24 hours
Power 115VAC
Dimensions 9 1/4”H x 17.6”W x 16”D
Weight 30 lbs.

California Analytical Model 300FID
THC Analyzer (Unheated)

The CAI Model 300FID THC analyzer employs a flame ionization detector. This instrument, unlike most other THC analyzers, uses capillary tubes and electronic pressure controllers for gas pressure regulation. This feature allows for automatic flame optimization at varying elevations. The analyzer includes front panel ignition and zero/span potentiometers.

Ranges

0-10, 30, 100, 300, 1000, 3000, 10000, 30000 ppm

Detection Method

FID

Sample Gas Input

1/4-inch Tube; 1.5 lpm

Analog Outputs

0-10 Vdc, 4-20mA

Power Requirement

110 VAC/60 Hz

Shipping & Weight

32x25x14 – 61 lbs

Technician’s Notes All THC analyzers are set-up for propane calibration standards, but can be reconfigured for methane standards upon request. The instrument requires a blended fuel of 40% hydrogen and 60% helium and zero grade combustion air. Helium balanced fuel minimizes the oxygen synergism phenomenon and is recommended by US EPA. Both fuel and air can be obtained from Cherokee separately.

California Analytical Model 300HFID
THC Analyzer (Heated)

The CAI Model 300HFID THC analyzer employs a heated flame ionization detector, heated sample pump and heated flow path designed to maintain the sample gas above dew point until analysis. This instrument, unlike most other THC analyzers, uses capillary tubes and electronic pressure controllers for gas pressure regulation. This feature allows for automatic flame optimization at varying elevations. The analyzer includes front panel ignition and zero/span potentiometers.

Ranges

0-10, 30, 100, 300, 1000, 3000, 10000, 30000 ppm

Detection Method

FID

Sample Gas Input

1/4-inch Tube; 1.5 lpm

Analog Outputs

0-10 Vdc, 4-20mA

Power Requirement

110 VAC/60 Hz, Dedicated 15-20 amp service

Shipping & Weight

32x25x14 – 85 lbs

Technician’s Notes All THC analyzers are set-up for propane calibration standards, but can be reconfigured for methane standards upon request. Most of these instruments require a blended fuel of 40% hydrogen/ 60% helium and zero grade combustion air. Helium balanced fuel minimizes the oxygen synergism phenomenon and is recommended by US EPA. Both fuel and air can be obtained from Cherokee separately.

California Analytical Model 300 HFID
Methane/Non-Methane Analyzer


The California Analytical Model 300 HFID THC analyzer incorporates a heated flame ionization detector and a proprietary hydrocarbon cutter. The cutter responds to better than 90% of the methane in a gas sample, while responding to less than 2% of the ethane and 0.1% of all other hydrocarbons. When in THC mode, the analyzer will respond to all hydrocarbons in a gas stream. In methane mode, the instrument will only respond to the methane in a gas stream. The non-methane content is the total hydrocarbon content, less the methane content. Ranging is selectable from 10 ppm to 30,000 ppm.

Manufacturer California Analytical Instruments
Analysis Method Flame Ionization Detector
Range 10 to 30,000 ppm
Response Time 90% of full scale in 1.5 seconds
Sample Flow Rate 3 liter/min. + 1.5 liter/ min.
Noise Less than 0.5% of full scale
Zero & Span Drift Less than 1% of full scale per 24 hours
Analog Output 0 -10 VDC and 4 to 20mA DC
Power 115VAC
Dimensions 5 1/4”H x 19”W x 8”D
Weight 38 lb.

Service Note The California Analytical THC analyzers require the use of 40% hydrogen / 60% helium fuel. The MSA THC Analyzer can operate using either pure hydrogen or the helium fuel mixture. All the analyzers require an external combustion air supply. For extended use try our combustion air pack rather than compressed air.

California Analytical Model 300 HFID-M
THC/Methane Analyzer (Heated)

The California Analytical Model 300 HFID-M THC/Methane analyzer employs a single heated flame ionization detector and a proprietary hydrocarbon cutter. The catalytic cutter responds to >90% of the methane in a gas sample, while responding to <2% of the ethane and 0.1% of all other hydrocarbons. When in THC mode, the analyzer will respond to all hydrocarbons in a gas stream. In methane mode, the instrument will only respond to the methane in a gas stream. The non-methane content is the total hydrocarbon content, less the methane content. This instrument, unlike most other THC analyzers, uses capillary tubes and electronic pressure controllers for gas pressure regulation. This feature allows for automatic flame optimization at varying elevations. The analyzer includes front panel ignition and zero/span potentiometers.

Ranges

0-10, 30, 100, 300, 1000, 3000, 10000, 30000 ppm

Detection Method

Flame ionization detector                                       

Sample Gas Input

1/4-inch Tube; 1.5 lpm

Analog Outputs

0-10 Vdc, 4-20mA (please specify if desired)

Power Requirement

110 VAC/60 Hz

Shipping & Weight

32x25x14 – 85 lbs

Technician’s Notes All THC analyzers are set-up for propane calibration standards, but can be reconfigured for methane standards upon request. The instrument requires a blended fuel of 40% hydrogen and 60% helium and zero grade combustion air. Helium balanced fuel minimizes the oxygen synergism phenomenon and is recommended by US EPA. Both fuel and air can be obtained from Cherokee separately.

VIG Industries Model 200-1
THC/Methane Analyzer(Heated)

The VIG Model 200-1 THC/Methane analyzer employs a single heated flame ionization detector and GC column for separation of the methane and non-methane hydrocarbon components. A sample is injected into the column and the methane component passes through to the detector; the remaining sample is then back flushed through the column and to the detector to obtain the non-methane portion of the sample. Sample loop duration is approximately 2.5 minutes.


Ranges

0-10, 100, 1000, 10000 ppm OR
0-100, 1000, 10000, 100000 ppm (specify)

Detection Method

FID/GC                                                                

Sample Gas Input

1/4-inch Tube; 4 lpm

Analog Outputs

0-10 Vdc, 4-20mA (please specify if desired)

Power Requirement

110 VAC/60 Hz

Shipping & Weight

32x25x14 – 85 lbs

Technician’s Notes This analyzer is set-up for blended propane/methane calibration standards. Single component calibration standards can be used but will greatly increase calibration time. The instrument requires a 100% hydrogen fuel, combustion air source, carrier gas and secondary air source for an air-actuated valve. Calibration standards, fuel and air can be obtained from Cherokee separately.

VIG Industries Model 210
THC/Methane/Ethane Analyzer (Heated)

The VIG Model 210 THC/Methane/Ethane analyzer employs two heated flame ionization detectors. One detector measures total hydrocarbons continuously; the second detector is coupled to a GC column for the separation of the methane, ethane and non-methane-ethane components. A sample is injected into the column and the methane component passes through to the detector; the ethane component then follows through to the detector for analysis. The remaining sample is then back flushed through the column and to the detector to obtain the non-methane/ethane portion of the sample. Sample loop duration is approximately 3 minutes.

Ranges

0-10, 100, 1000, 10000 ppm OR
0-100, 1000, 10000, 100000 ppm (specify)

Detection Method

FID and FID/GC                                                   

Sample Gas Input

1/4-inch Tube; 4 lpm

Analog Outputs

0-10 Vdc, 4-20mA (please specify if desired)

Power Requirement

110 VAC/60 Hz

Shipping & Weight

32x25x14 – 85 lbs

Technician’s Notes This analyzer is set-up for blended propane/methane/ethane calibration standards. Single component standards can be used but will greatly increase calibration time. The instrument requires a 100% hydrogen fuel, combustion air source, carrier gas and secondary air source for an air-actuated valve. Calibration standards, fuel and air can be obtained from Cherokee separately.

California Analytical Model ZRH-1
VOC Analyzer (Gasoline MACT)

The CAI Model ZRH VOC analyzer is a microprocessor-controlled instrument that employs a non-dispersive infrared detector. This unit provides a backlit front panel display with “push button” controls and adjustments.

Ranges

0-25, 50, 100% by volume

Detection Method

NDIR                                                                    

Sample Gas Input

1/4-inch Tube; 0.5 to 2 lpm

Analog Outputs

0-10 Vdc, 4-20mA

Power Requirement

110 VAC/60 Hz

Shipping & Weight

32x25x14 – 64 lbs

Cherokee Instruments Combustion Air Supply Pump Pack
The Cherokee combustion air supply is an air-purifying unit that is ideal for replacing bottled air to analyzers with such requirements. This unit supplies clean, dry air at up to 30 psig. The unit utilizes solid sorbent packed columns to purify and dry the air, and a diaphragm pump to pressurize the gas.

Gas Output

1/4-inch Tube; 30 psig

Power Requirement

110 VAC/60 Hz

Shipping & Weight

24x16x10 – 25 lbs

:: Back to Continuous Emissions Monitors ::

Our Affiliates

Teledyne API

Air Products & Chemical Gases
Apex Instruments, Inc.
AMATEK Western Research (Bovar)
Baldwin Environmental
California Analytical Instruments, Inc.
Cherokee Instuments
Emission Measurement Technology
Graseby / Andersen / General Metal Works
MSA Baseline
O’Brien Corporation
Pacwill Environmental
Spectra Gases, Inc.
STRATA
Telegan Gas Monitoring, LTD
Thermo Electron
Universal Analyzers


cherokee instruments cem rentals warranty
cems air quality emissions testing
emt stack testing consulting

Contact Us | Privacy Statement
©2007 Cherokee Instruments, Inc.