CEMS Accessories

Universal Model 1050SS Gas Conditioner

Apex Instruments 2-Stage Gas Conditioner
Baldwin Model 5210 Gas Conditioner
Baldwin Model 5210 Gas Conditioner (Low NOx)

Baldwin Testers Choice Gas Conditioner

Baldwin Model MP-425 Mini Portable Gas Conditioner
Universal Model 1050SS Gas Conditioner
Perma-Pure Permeation Tube Gas Conditioner
Cherokee Model 20D CEM Flow Control Panel
RATA Probe - 3-Point w/ Mixing Chamber



Universal Model 1050SS Gas Conditioner











The thermoelectric cooler from Universal uses the Peltier Effect to reduce moisture levels to concentrations manageable by dry basis analyzers. The conditioner is packaged such that it is easily incorporated into any CEM system.

The arrangement includes:
* Dual-Pass Thermoelectric Cooler (handles up to 40% water vapor)
* Dual-Head Peristaltic Pump
* Moisture Breakthrough Sensor
* Sample Pump
* Flow Control Rotameter (0 to 8 liters per minute)
* Hard-Mounted in Upright Shipping Case

Gas Connections

Inlet = 3/8-inch tube, Outlet = 1/4-inch tube

Flow Rate(s)

3-8 lpm

Power Requirement

110VAC/60 Hz

Shipping & Weight

28x23x17 – 107 lbs

Technican's Note High ambient temperature dramatically affects the efficiency of a thermoelectric conditioner. Please select Durinert coated or glass/kynar heat exchangers for SO2 or NO2 sampling applications.

Helpful Hint
If moisture does break through, the sample pump will automatically shut down to prevent damage to any attached gas analyzers. Remove the water condensate, lower your sample flow rate through the conditioner to maintain a <40o dewpoint, and continue sampling.


Apex Instruments 2-Stage Gas Conditioner



The Apex chiller incorporates the use of glass coil condensers to remove moisture from a gas sample. As all components are glass or Teflon, this chiller is excellent for sulfur compound testing.

The arrangement includes:
* Dual-Stage Glass Coil Condenser Arrangement
* Peristaltic Pump for Coolant Circulation and Moisture Removal
* Sample Pump
* Flow Control Rotameter (0 to 8 liters per minute)
* Hard-Mounted in Upright Shipping Case

Power Requirements 115 Volts AC
Shipping Size & Weight 1 Package / 35 lbs

Helpful Hint The customer must supply chilled water or coolant to the coil condensers via the supplied peristaltic pump. For extended operation, a refrigerant unit can be provided to chill coolant without the use of an ice bath.


Baldwin Model 5210 Gas Conditioner
The Baldwin Model 5210 gas conditioning system incorporates two 10-inch heat exchangers (one active one passive), dual-channel peristaltic pump, secondary filter, water slip sensor, Teflon coated sample pump and 0-10 lpm flow rotometer. All components are mounted onto a 19-inch rack bracket for quick deployment. The system can handle up to 40% water vapor at an ambient temperature of 70oF and flow rates up to 8 lpm.

Gas Connections

Inlet = 3/8-inch tube
Outlet = 1/4-inch tube

Flow Rate(s)

3-8 lpm

Power Requirement

110VAC/60 Hz

Shipping & Weight

28x23x17 – 99 lbs

Technician’s Notes High ambient temperature dramatically affects the efficiency of a thermoelectric conditioner. Please select Durinertâ coated or glass/kynar heat exchangers for SO2 or NO2 sampling applications.



Baldwin Model 5210 Gas Conditioner (Low NOx)
The Baldwin Model 5210 gas conditioning system in a low NOx configuration adds key items and details to the standard 5210 conditioner in order to efficiently transport low concentration NOx. Unique features include Durinertâ coated 10-inch heat exchangers and a Teflon headed pump that is dedicated for use on low NOx applications only.

In addition, the ceramic filter and Teflon tubing are completely replaced after every rental. This allows the system to maintain the inertness needed. The system can handle up to 40% water vapor at an ambient temperature of 70oF and flow rates up to 8 lpm.

Gas Connections

Inlet = 3/8-inch tube
Outlet = 1/4-inch tube

Flow Rate(s)

3-8 lpm

Power Requirement

110VAC/60 Hz

Shipping & Weight

28x23x17 – 99 lbs




Baldwin Testers Choice Gas Conditioner
The Baldwin Testers Choice gas conditioning system is an enclosed and weather resistant system that is designed for use at or near the sample extraction point. The system incorporates two 10-inch heat exchangers (one active one passive), dual-channel peristaltic pump, secondary filter, water slip sensor, Teflon coated sample pump and 0-10 lpm flow rotometer. All components are mounted onto a 19-inch rack bracket for quick deployment. The system can handle up to 40% water vapor at an ambient temperature of 70oF and flow rates up to 8 lpm.


Gas Connections

Inlet = 3/8-inch tube, Outlet = 1/4-inch tube

Flow Rate(s)

3-8 lpm

Power Requirement

110VAC/60 Hz

Shipping & Weight

20x14x26 – 86 lbs



Baldwin Model MP-425 Mini Portable Gas Conditioner

The Baldwin Mini Portable gas-conditioning system is miniature gas conditioning system designed for flow rates up to 4 lpm. It incorporates two 2.5-inch heat exchangers (one active one passive), dual-channel peristaltic pump, water slip sensor, sample pump and 0-5 lpm flow rotometer. The MP-425 is excellent for portable gas analyzers or temporary CEMS that only use a few liters of gas flow.

Gas Connections

1/4-inch tube (inlet and outlet)

Flow Rate(s)

1-4 lpm

Power Requirement

110VAC/60 Hz

Shipping & Weight

21x14x15 – 47 lbs



Universal Model 1050SS Gas Conditioner
The Universal Model 1050SS gas conditioning system incorporates two 10-inch heat exchangers (one active one passive), dual-channel peristaltic pump, secondary filter/water slip sensor, Teflon coated sample pump and 0-10 lpm flow rotometer. All components are mounted onto a 19-inch rack bracket for quick deployment. The system can handle up to 40% water vapor at an ambient temperature of 70oF and flow rates up to 8 lpm.

Gas Connections

Inlet = 3/8-inch tube
Outlet = 1/4-inch tube

Flow Rate(s)

3-8 lpm

Power Requirement

110VAC/60 Hz

Shipping & Weight

28x23x17 – 107 lbs

Technician’s Notes High ambient temperature dramatically affects the efficiency of a thermoelectric conditioner. Please select Durinertâ coated or glass/kynar heat exchangers for SO2 or NO2 sampling applications.


Perma-Pure Permeation Tube Gas Conditioner
The Perma-Pure heated gas conditioning system incorporates a Nafion® selective permeable membrane drying column to remove water vapor from a gas sample without removing water soluble components of interest. Stack gases are passed through a secondary sample filter and then through the drying column. A counter-flow of compressed, dry air is passed along the drying column to continuously wick moisture away. The system can handle up to 30% water vapor at flow rates up to 6 lpm.

Gas Connections

Inlet = 1/4-inch tube
Outlet = 1/4-inch tube
Dry Air = 1/4-inch tube

Flow Rate(s)

3-8 lpm

Power Requirement

110VAC/60 Hz

Shipping & Weight

32x25x14 – 64 lbs

Technician’s Notes Cherokee recommends the use of a heated head pump to push stack gas through the conditioner. Heated head pumps can be rented separately.


Cherokee Model 20D CEM Flow Control Panel

The Cherokee 20D CEM flow control panel incorporates 4 gas analyzer outputs, 10 cal gas inputs, and rotometers for each analyzer gas, cal gas flow and the bypass flow.  Included is also a sample/calibration gas pressure gauge and a pressure regulator. This unit can be operated either the automatic mode which is computer controlled or the manual mode.

Gas Connections

All Connections 1/4-inch (7 total)

Analyzers supported

4 or 5

Power Requirement

110VAC/60 Hz

Shipping & Weight


RATA Probe, 3-Point w/ Mixing Chamber
The RATA probe is designed to simultaneously extract a gas sample from three individual points along a single traverse. Extracted gases are combined in a heated mixing chamber prior to transport to your instrument bank. The probe is designed to accept three 1/2-stainless steel tubes that are cut to length to meet the exact source configuration. Flow rates through each tube are maintained via heated orifice. This unit is supplied with a 3/8-inch tube connection for sample gas extraction, a 1/4-inch tube connection for calibration gas injection, power umbilical and a dual-station heat controller.

Gas Connections

3/8-inch tube (sample)
1/4-inch (calibration)

Probe Composition

2.5-inch OD orifice block
w/ three 1/2-inch tube connections

Filter Composition

Sintered SS (x3)

Power Requirement

110VAC/60 Hz

Shipping & Weight

RATA Probe = 36x16x14 – 27 lbs

Technician’s Notes Stainless steel extensions are not provided with the system but can be purchased separately.

:: Back to CEMS Accessories ::

Our Affiliates

Teledyne API

Air Products & Chemical Gases
Apex Instruments, Inc.
AMATEK Western Research (Bovar)
Baldwin Environmental
California Analytical Instruments, Inc.
Cherokee Instuments
Emission Measurement Technology
Graseby / Andersen / General Metal Works
MSA Baseline
O’Brien Corporation
Pacwill Environmental
Spectra Gases, Inc.
STRATA
Telegan Gas Monitoring, LTD
Thermo Electron
Universal Analyzers


cherokee instruments cem rentals warranty
cems air quality emissions testing
emt stack testing consulting

Contact Us | Privacy Statement
©2007 Cherokee Instruments, Inc.